TW

Tare Window

TW


Command Group: Checkweigher

Access:

Network interfaces:

RW

CANopen

SDO2500sub06

MODbus

240A,2

TW - Set the tare window

PROFIbus

read 38,6 write 38,134


Synopsis:
CommandResponse
GetTWW<Value>
SetTW <Value>OK (or ERR)
Valid forMin. valueMax. value
141.181 0 65535
141.184 0 65535
141.185 0 65535
141.186 0 65535
142.181 0 65535
142.184 0 65535
142.185 0 65535
142.186 0 65535
143.181 0 65535
143.184 0 65535
143.185 0 65535
151.181 0 65535
151.184 0 65535
151.186 0 65535
152.181 0 65535
152.184 0 65535
162.181 0 65535
179.181 0 65535
181.181 0 65535
64.181 0 65535
72.181 0 65535
78.183 0 65535
88.183 0 65535



TW Set the Tare Window in in counts (digits) without decimal point.
Tare window (TW) allows an automatic Tare update.
If TW = 0 this function is not active.
If TW = 100, this means a new tare value will be taken when the net average weight of an empty scale is within 100 counts or division of zero. The new average tare value is calculated over the average tare time defined by TI. If the tare average is outside tare window, the tare will not be updated.
Factory default is 0 (zero).

See also RW, TT, TS, DT, TI and HT