TN

Tare Non volatile.

TN


Command Group: Calibration

Access:

Network interfaces:

TAC protected

RW

CANopen

SDO2300sub13

MODbus

2224,2

TN - Set/Clear non-volatile tare.

PROFIbus

read 3,19 write 4,19


Synopsis:
CommandResponse
GetTNT:<Value>
SetTN <Value>OK (or ERR)
Valid forMin. valueMax. value
141.181 0 1
141.184 0 1
141.185 0 1
141.186 0 1
142.181 0 1
142.184 0 1
142.185 0 1
142.186 0 1
143.181 0 1
143.184 0 1
143.185 0 1
151.181 0 1
151.184 0 1
151.186 0 1
152.181 0 1
152.184 0 1
162.181 0 1
179.181 0 1
181.181 0 1
64.181 0 1
64.184 0 1
72.181 0 1
78.183 0 1



TN - Set/Clear Non-volatile tare.
TN 0<CR> Set the tare mode to volatile (Default).
TN 1<CR> Set the tare mode to non volatile - every set/clear tare will write the tare value directly to the EEPROM.
The tare mode is saved by the CS command and is TAC protected.

Valid from Firmware 72.181.v.4.37 and 78.183.v.2.49