ST

Set Tare

ST


Command Group: Zeroing

Access:

Network interfaces:

W

CANopen

RPDO1,08

MODbus

2061,1,08

ST - Set the tare point

PROFIbus

write 30,0


Synopsis:
CommandResponse
SetSTOK (or ERR)
Valid forMin. valueMax. value
141.181    
141.184    
141.185    
141.186    
142.181    
142.184    
142.185    
142.186    
143.181    
143.184    
143.185    
151.181    
151.184    
151.186    
152.181    
152.184    
162.181    
179.181    
181.181    
64.181    
64.184    
68.181    
68.183    
69.181    
72.181    
72.184    
78.183    
78.184    
88.183    
88.184    
88.185    



ST This command will activate the net weighing function by storing the current weight value as a tare.

The weight signal must be “stable” within the limits set by NR (No Motion Range) and NT (NoMotion Time) commands for the “signal stable” bit to be active and set tare command to be accepted.

Note: The LDM88 (all versions) supports writing the Tare value thru:
CANopen:SDO2100sub0D
MODbus:2118,2
PROFIbus:read 18,13 write 31,13

See also SZ, RZ, RT, and IS.