OM

IO mask

OM


Command Group: DigitalIO

Access:

Network interfaces:

RW

CANopen

SDO2100sub0C

MODbus

2116,2

OM - Set the IO mask.

PROFIbus

read 18,12 write 31,12


Synopsis:
CommandResponse
GetOMOM:<Value>
SetOM <Value>OK (or ERR)
Valid forMin. valueMax. value
141.181 0 111
141.184 0 111
141.185 0 111
143.181 0 111
143.184 0 111
143.185 0 111
151.181 0 111
152.181 0 111
179.181 0 11
64.181 0 1111
64.184 0 1111
72.181 0 111
72.184 0 111



OM In order to control the outputs from the host application the outputs must be configured using the OM command. A “1” bit in the mask will open the corresponding output channel for outputs from the IO command and a “0” bit will leave the channel controlled by the setpoint. Issuing the OM command without any parameters returns the current mask in the form OM:0011. Change the mask by issuing the IM command with the appropriate four-digit value in the form OM 0001.
NOTE: This command is called IM on other H&B devices.

See also IN, IO, An, Hn, Sn.