HT

Hold Time

HT


Command Group: Checkweigher

Access:

Network interfaces:

RW

CANopen

SDO2500sub05

MODbus

2408,2

HT - Set the hold time

PROFIbus

read 38,5 write 38,133


Synopsis:
CommandResponse
GetHTH<Value>
SetHT <Value>OK (or ERR)
Valid forMin. valueMax. value
141.181 0 65535
141.184 0 65535
141.185 0 65535
141.186 0 65535
142.181 0 65535
142.184 0 65535
142.185 0 65535
142.186 0 65535
143.181 0 65535
143.184 0 65535
143.185 0 65535
151.181 0 65535
151.184 0 65535
151.186 0 65535
152.181 0 65535
152.184 0 65535
162.181 0 65535
179.181 0 65535
181.181 0 65535
64.181 0 65535
72.181 0 65535
78.183 0 65535
88.183 0 65535



HT Set the Hold Time in milliseconds [ms]. During the Hold Time the weight value must be over setpoint that a digital output can be switched. This means that a short signal peak will not lead to the switching of a digital output.

See also RW, TT, TS, DT, TW, TI, GA, SA, TE, TR.