GA

Get average

GA


Command Group: Checkweigher

Access:

Network interfaces:

R

CANopen

SDO2900sub06

MODbus

2008,2

GA - Get Average - returns the current average weight value

PROFIbus

read 10,0


Synopsis:
CommandResponse
GetGAA<Value>
Valid forMin. valueMax. value
141.181    
141.184    
141.185    
141.186    
142.181    
142.184    
142.185    
142.186    
143.181    
143.184    
143.185    
151.181    
151.184    
151.186    
152.181    
152.184    
162.181    
179.181    
181.181    
64.181    
68.181    
72.181    
78.183    
88.183    



GA Issuing the GA command returns the latest average weight value by using the MT setup.
On System80/MCS-64 with CGM85 CANopen gateway it is not necessary to ask for this. The average result is sent in a TPDO2 when ready, or retriggered.

See also RW, TT, TS, MT DT, TW, TI, GA, SA, TE, TR.