BR

Set Baudrate

BR


Command Group: Communication

Access:

Network interfaces:

RW

CANopen

MODbus

BR - Read/modify the baudrate

PROFIbus


Synopsis:
CommandResponse
GetBRB<Value>
SetBR <Value>OK (or ERR)
Valid forMin. valueMax. value
141.181 9600 115200
141.184 9600 115200
141.185 9600 115200
141.186 9600 115200
142.181 9600 115200
142.184 9600 115200
142.185 9600 115200
142.186 9600 115200
143.181 9600 115200
143.184 9600 115200
143.185 9600 115200
151.181 9600 115200
151.184 9600 115100
151.186 9600 115100
151.186 9600 115200
152.181 9600 115200
152.184 9600 115200
162.181 9600 460800
179.181 9600 115200
181.181 9600 460800
64.181 9600 460800
64.184 9600 460800
68.181 9600 115200
68.183 9600 115200
69.181 9600 115200
72.181 9600 115200
72.184 9600 115200
78.183 9600 115200
78.184 9600 115200
88.183 115200 115200
88.184 115200 115200
88.185 115200 115200



BR Get or set the Serial Communication speed of the device .
LDU/DAS possible rates: 9600, 19200, 38400, 57600, 115200.
LDU/DAS Factory default setting : 9600 bps.
LDM permanent setting : 115200 bps.

See also AD, CL, DX, and OP