AV

Show Internal mV/V Value

AV


Command Group: Weight

Access:

Network interfaces:

R

CANopen

SDO2900sub12

MODbus

2092,2

AV - Show the internal mV/V Value

PROFIbus


Synopsis:
CommandResponse
GetAVV<Value>
Valid forMin. valueMax. value
141.181 -32000 32000
141.184 -32000 32000
142.181 -32000 32000
142.184 -32000 32000
143.181 -32000 32000
143.184 -32000 32000
64.181 -32000 32000
64.184 -32000 32000



AV Shows the Internal mV/V value.

This command shows the internal mV/V weight value in the same format as the mV/V value given when using the AZ or AG command.
This functions like the GS command except the mV/V is ‘live’ data.

See also:  AZ, AG and GS