A2

Sp 2 Source

A2


Command Group: Setpoints

Access:

Network interfaces:

RW

CANopen

SDO2800sub03

MODbus

2068,2 select 2067,1,2

A2 - Select Gross/net source for setpoint 2

PROFIbus

read 29,$12 write 29,$42


Synopsis:
CommandResponse
GetA2A2:<Value>
SetA2 <Value>OK (or ERR)
Valid forMin. valueMax. value
141.181 0 12
141.184 0 12
141.185 0 12
141.186 0 12
142.181 0 12
142.184 0 12
142.185 0 12
142.186 0 12
143.181 0 12
143.184 0 12
143.185 0 12
151.181 0 2
151.184 0 2
151.186 0 2
152.181 0 2
152.184 0 2
64.181 0 2
72.181 0 8
88.183 0 1



A2 Set the source for setpoint channel 2. This source will trigger the required action of the output channel relay, according to the settings of the controls S2, H2 and P2.
Issuing the A2 command without any parameters returns the current value in the form A2:+00001.

0 = Gross weight as setpiont source.
1 = Net weight as setpoint source.
2 = Average.

Example: If you want the Setpoint to be trigged on the Net weight, set the value to 1.

NB! Special values for DAD141 (A0, A1, A2)
00 - Gross Weight.
01 - Net Weight.
02 - Peak.
03 - Average.
04 - Hold.
05 - Peak to Peak.
06 - Valley.
07 - Error.
08 - Mass Flow.
09 - Batch Loss Weight.
10 - Bit from LIW control.
11 - Average ready
12+ - OFF.

NB! Special values for DAS72 (A1, A2, A3)
00 - Gross Weight.
01 - Net Weight.
02 - Peak.
03 - Average.
04 - Hold.
05 - Peak to Peak.
06 - Valley.
07 - Error.
08+ - OFF.

See also A0, A1, A3, S0, S1, S2, S3, H0, H1, H2, H3, P1, P2, P3.